F.75 on a Vaillant boiler means the boiler did not detect the expected rise in pressure when its pump started. Check the pressure gauge: if it reads below 1 bar, top it up and reset the boiler. If the pressure is already fine, the pressure sensor, pump or expansion vessel has usually failed and needs a Gas Safe engineer.
For other Vaillant codes, see our Vaillant fault codes hub.
Vaillant’s own fault code page limits homeowner checks to the pressure:

Safe for you to try
Gas Safe engineer only
Always check your engineer is on the Gas Safe Register.
This is the cause we find most often. Dirt and sludge in the heating water can block the sensor, so it stops reading the pressure change. A new sensor is usually quicker and more reliable than cleaning the old one. When we fit one, we also clean out the magnetic filter and add fresh inhibitor, so sludge does not block the new sensor.

If the pump does not run, the pressure does not change when it should. A pump that is silent and not vibrating when the boiler fires is a sign it has failed.
The expansion vessel absorbs pressure changes as the water heats. If it loses its air charge, the pressure swings up and down, which can trigger F.75 and make the pressure relief valve drip.

If you keep having to top up, water is escaping somewhere. Fixing the leak stops F.75 coming back.
From the job: ecoTEC Plus 825, sensor clogged with sludge
ecoTEC Plus 825 with F.75. The pressure sensor was clogged with black sludge. New sensor in, then cleaned out a magnetic filter that hadn’t been opened in years and added fresh inhibitor.
Expert notes by Jamie Watkins, Gas Safe registered engineer (Gas Safe ID 6115118), Homecure Plumbers – Gas Safe Reg 505421
From the job: ecoTEC Plus 835, pressure swinging up and down
ecoTEC Plus 835 showing F.75, pressure swinging up and down. The expansion vessel had lost its charge. Recharged it to 1 bar and the fault cleared. If it goes flat again it will need a new vessel.
Expert notes by Kevin Saban, Gas Safe registered engineer (Gas Safe ID 6115119), Homecure Plumbers – Gas Safe Reg 505421
Repairs from £95 + VAT for the first hour, including diagnosis (or a fix if it can be done within the first hour with no parts needed), no callout charge. Typical costs, including parts and labour, fitted:
| Repair | Typical cost |
|---|---|
| Pressure sensor replacement | from £215 + VAT |
| Pump replacement | from £289 + VAT |
| Expansion vessel recharge | from £95 + VAT |
| Expansion vessel replacement | from £214 + VAT |
Subject to diagnosis; prices vary depending on boiler model and job complexity. Prices apply during office hours; parking or the congestion charge may be added.
Book a Vaillant boiler repair or call 0203 504 4000.
Only if the pressure is low, by topping it up. The sensor, pump and expansion vessel are inside the boiler, so they need a Gas Safe registered engineer.
No. The boiler shuts down to protect itself, so you will lose heating and hot water until it is fixed.
Sources: Vaillant: boiler fault codes · Gas Safe Register