Breakdowns, fault diagnostics and annual servicing.
Combi diverter valve repair, Acton W3
Kevin went out to a Worcester combi on Twyford Avenue. The radiators were getting warm whenever the hot tap was running, and the hot water itself was only lukewarm, which pointed straight at the diverter valve. He isolated the gas and power, drained the boiler down and took the valve out. The cartridge was sticking halfway, so the water was being split between the heating and the plate heat exchanger. He fitted a new diverter cartridge, refilled to 1.2 bar and bled the boiler through the auto air vent. With the heating off he ran the kitchen tap. The radiators stayed cold and the hot water came up to temperature in under a minute.
See our boiler repairs & servicing in Acton →Pilot light keeps going out, thermocouple fixed in Bromley, BR1
An old Ideal Mexico floor standing boiler on Widmore Road wouldn't keep its pilot lit. The customer could light it, but as soon as they let go of the button it went out. The flame was small and yellow, so Jamie cleaned the pilot assembly first, then tested the thermocouple. It wasn't putting out enough to hold the gas valve open. He fitted a new thermocouple and the pilot stayed lit. He then gave the boiler a service and checked the flue. These old boilers are reliable but parts are getting harder to find, so he talked the customer through the options for when it does need replacing.
See our boiler repairs & servicing in Bromley →Boiler service and pump noise fixed in Croydon, CR0
The customer on Birdhurst Road booked an annual service and also mentioned a humming from the airing cupboard at night. Ryan did the service first. He cleaned the burner and condensate trap, checked the expansion vessel charge and took flue gas readings, all within the manufacturer’s figures. The noise was coming from the external pump. It was set to its highest speed, pushing water round faster than the system needed and making the pipes and radiator valves whine. He turned it down to speed two and bled air from the pump head and the top radiators. The hum stopped and the heating still came up to temperature without trouble.
See our boiler repairs & servicing in Croydon →Blocked flue terminal cleared on a Potterton in Finchley, N12
A Potterton Promax on Woodside Park Road kept locking out on start up, usually first thing in the morning. Jamie found the air pressure switch wasn't making when the fan ran up. Following it back, he went outside and found the flue terminal, which sits high up under the eaves, packed with twigs from a nest. He took the old guard off from a ladder and cleared it out, then checked the switch tube and its connections were clear inside. Flue analysis afterwards was good and the switch made every time. He fitted a new terminal guard with a tighter mesh.
See our boiler repairs & servicing in Finchley →Random boiler lockouts traced to the fused spur, Hillingdon UB10
The customer on Harlington Road said the Alpha combi would go out at random, sometimes twice a day, then work fine after a reset. Ryan checked flame signal and gas pressure, both within range. The condensate route was clear too. He could find nothing wrong inside the boiler. The fault was outside it. The fused spur feeding the boiler had a loose neutral terminal, browned with heat. The supply was dropping out for a split second when the fan started. He isolated the circuit, replaced the spur and remade the boiler flex into it. It has run without a lockout since.
See our boiler repairs & servicing in Hillingdon →Baxi E160 fan fault traced to a chafed loom, Lewisham SE13
The Baxi on Algernon Road was throwing E160 and locking out. Jamie checked for fan voltage at the PCB, which was there. At the fan plug it was not. The loom had been rubbing on the edge of the casing and one wire had worn through its insulation and broken. He replaced the fan loom and tied it away from the edge, and the boiler fired normally. A full service was done while the case was off.
See our boiler repairs & servicing in Lewisham →Back boiler service, Poplar E14
There are not many back boilers left, but the Baxi behind the gas fire on Bazely Street is still going. Ryan took the fire out to get at the boiler, cleaned the burner and checked the flue with a smoke pellet. The draw was strong and there was no spillage at the fire or the boiler. He replaced the perished fibre seal on the closure plate, set the gas pressure and put it all back together. He also talked the owner through replacement options for when the time comes, without any pressure to decide.
See our boiler repairs & servicing in Poplar →Gas tightness failure traced, Southwark SE1
Jamie went to Merrick Square to fit a new hob, and the gas tightness test failed before he even started. Nothing could be smelt, but the gauge kept creeping down. He tested each section and narrowed it to an old spur under the kitchen floor that once fed a gas fire. The cap on the end had been fitted with no jointing compound and was letting gas by slowly. He cut the spur back to the main run, capped it properly and the system passed. Then the hob went in.
See our boiler repairs & servicing in Southwark →Zone valve motor replaced in Walthamstow, E17
Upstairs radiators came on, downstairs stayed cold. Ryan traced the wiring from the programmer to the two zone valves in the airing cupboard on Orford Road. The downstairs valve motor was humming but not opening, and the manual lever was loose. He swapped the motor head, which on that make clips straight onto the valve body without draining down. He checked the microswitch was bringing the boiler on. The programmer had also lost its settings after a power cut, so he set the times back up with the owner before leaving.
See our boiler repairs & servicing in Walthamstow →