If a radiator with a thermostatic radiator valve (TRV) stays cold, the pin under the TRV head has usually stuck. Take the head off, free the pin by gently working it up and down, and put the head back. It takes about five minutes.
If the valve leaks or will not work once the pin is free, it needs replacing. That means draining the heating system, which is a job for a heating engineer.
The TRV head contains a wax or liquid capsule that expands as the room warms up. As it expands it presses on a pin in the valve body, which closes the valve and cuts the flow of hot water into the radiator. The numbers on the head are a comfort setting, not degrees. The Energy Saving Trust explains how to use TRVs and other heating controls.

| What you notice | Most likely cause |
|---|---|
| One radiator stays cold while the others heat up | TRV pin stuck down. |
| Radiator stays hot even on the lowest setting | TRV pin stuck up, or a faulty TRV head. |
| Cold at the top, warm at the bottom | Air in the radiator. Bleed it. |
| Warm at the top, cold at the bottom | Sludge in the system. Needs a system clean or power flush. |
| Water around the valve | A leaking valve or joint. |
With the heating off, open the bleed valve with a radiator key until the hissing stops and water appears, then close it. Check the boiler pressure afterwards and top it up if it has dropped below 1 bar.
The lockshield valve on the other end of the radiator (usually under a plastic cap) sets how much water flows through it. Opening the lockshields on the coldest radiators a little more, and closing down the ones nearest the boiler, evens out the heat.
Safe for you to try
Call us
These need a heating engineer. Draining and refilling a sealed system also means repressurising and bleeding it afterwards.

If only the head is faulty, a replacement head that fits your valve can be swapped without draining anything. If the valve body is leaking or broken, the system has to be drained before the old valve comes off.
Replacing a TRV means draining down and refilling the system, which takes at least 2 hours: from £190 + VAT, plus £79 + VAT per TRV fitted (or £52 + VAT per standard radiator valve). Subject to diagnosis; prices vary depending on the job and access. Prices apply during office hours; parking or the congestion charge may be added.
See our central heating services or call 0203 504 4000.
From the job: a cold back bedroom radiator
Back bedroom radiator staying cold. The TRV pin had seized, so I took the head off and worked the pin with pliers until it moved freely. Radiator was warm in ten minutes.
Expert notes by Kevin Saban, Gas Safe registered engineer (Gas Safe ID 6115119), Homecure Plumbers – Gas Safe Reg 505421
Pins usually stick after the summer when the heating has been off for months. Turning each TRV to its highest setting at the end of the heating season helps stop this.
Not the one in the room with your main room thermostat. If its TRV shuts off before the room thermostat is satisfied, the boiler keeps running.